Updated November 22, 2026 · Free online reference
Follow the troubleshooting steps
Investigate motor vibration with checks for alignment, supports, couplings, driven equipment, bearings, single phasing and rotor balance.
Tap or click a fault check for troubleshooting steps, a visual guide and a practical tip. If that cause is not confirmed, follow the false path to the next check. The true arrow points to the fault check to open. Several faults can exist together; the order is a suggested sequence, rather than a universal ranking of how often faults occur.
Before inspection: isolate all energy sources, follow lockout/tagout and verify absence of voltage. Control stored electrical and mechanical energy. Energized measurements are for qualified electrical personnel using the site’s approved procedure and correctly rated equipment. Use the motor and machine manuals for specific limits and repairs.
- Motor misalignedTap/Click if this fault is seen
- Weak supportTap/Click if this fault is seen
- Coupling out of balanceTap/Click if this fault is seen
- Driven equipment unbalancedTap/Click if this fault is seen
- Defective bearingsTap/Click if this fault is seen
- Bearings not in lineTap/Click if this fault is seen
- Balancing weights shiftedTap/Click if this fault is seen
- Single phasingTap/Click if this fault is seen
- Excessive end playTap/Click if this fault is seen
- Rotor out of balanceTap/Click if this fault is seen
Frequently asked questions
How do I investigate Motor Vibrates?
Start with the first applicable fault check and compare its checks with the machine’s actual symptoms. If the cause is not confirmed, move to the next fault check. More than one fault can be present; verify the repair at normal load and speed.
Can I use every check on any motor?
Choose only the checks that apply to the motor design and equipment. Electrical testing and repairs require qualified personnel and the site’s approved procedures. Manufacturer-specific ratings, clearances, lubrication and wiring take precedence.
Source references and further learning
This general guide helps organize fault finding. Manufacturer manuals determine the correct tests, tolerances, lubricant quantities and repair methods for the actual motor.
- Koldwater Motor Control Training for motor and control-circuit fundamentals.
- Electrical and PLC Troubleshooting Training for systematic fault finding.
- WEG W20 installation, maintenance and troubleshooting manual — examples of motor checks and manufacturer-specific maintenance instructions.
- WEG wound-rotor motor manual — examples of slip-ring, brush and bearing maintenance. Apply the manual for your own motor.
- OSHA electrical work practices — isolation, verification and qualified-person requirements.